Driver controller TKS9
2017-05-16 09:51 Click£ºtimes
TKS9 type driver controller
I. overview
The TKS9 type driver controller is used for DF8, DF4B and DF 4C locomotives. The controller is simple in structure, flexible in operation, small in size, light in weight, high in safety, high in reliability and long in life, and less maintenance or maintenance free. The quick action switch adopts the sealed contact module of German technology. It has large capacity, quick acting type, forced break and sealed structure, and the contact protection level is over IP60. The CA- 20JA socket is connected with the external circuit.
The reference standard:
GB2423.4 basic environmental test procedures for electrical and electronic products -- Test Db: alternating wet and hot test methods
GB4207 solid insulating materials - Determination of relative creepage index and leak resistance trace index under wet conditions
GB5169.4 fire tests for electrical and electronic products -- Test methods and guidelines for glowing wires
Basic technical requirements for TB1333 locomotive electric equipment
The normal use of environmental conditions:
A) no more than 2500m above sea level;
B) maximum ambient air temperature: altitude less than 1000m at 45 DEG C; the elevation of 1000 ~ 2500m, from 45 degrees elevation increases every 0.5 DEG 100m degradation.
C) minimum ambient air temperature is -25 DEG C and allowed to be stored at -45 degrees c;
(d) ambient air humidity: the wettest monthly average relative humidity is not greater than 90% (the average monthly minimum temperature is not more than 25 degrees Celsius);
E) the inclination relative to the normal position is not greater than 10 degrees;
F) relative to the locomotive of the vertical, horizontal and vertical butthetraditionalsimulationphase F 1 ~ 50Hz sinusoidal vibration, the vibration acceleration when the frequency of F was 1 ~ 10Hz (equal to 0.1fg g for the acceleration of gravity, can be simplified as 10m /s 2); when the frequency of F is 10 ~ 50Hz is equal to 1g for locomotive; coupled impact, arouse the locomotive along the longitudinal acceleration is not greater than 3g;
G) mounted in a car body (or box) that can protect against rain, snow, wind and sand.
Two. Main technical parameters
Rated voltage of 2.1 contact (Ue):DC110V
2.2 contact rated operating current (Ie):DC 1A
3.3 contact heating current (Ith): DC 10A
2.4 weight: less than 10Kg
TAG£º