Your location:home > News >

Rail Measuring Equipment

2016-11-22 17:54      Click:times
CAT (Corrugation Analysis Trolley)

Technical Data: CAT

interval at which data are saved

1mm or 2mm

Output compatible with requirements of 

EN 13231-3:2006 and 2012

EN ISO 3095:2005

EN 15610:2009

Measuring speed (within +/-25%)

0.5m/s (1mm interval) 

1m/s (2mm interval)

Output 

raw and filtered displacements

moving average amplitudes (RMS and peak-to-peak) vs. distance

percentage exceedences

one-third octave spectra

exceedence reports (to assist grinding)

ASCII data

graphs to cut-and-paste directly in reports

Precision of measurements (displacement)

0.01μm

Repeatability

Better than 

0.5μm RMS 10-30mm

1μm RMS 30-100mm

2μm RMS 100-300mm

Filters, built-in

10-30mm, 30-100mm, 100-300mm, 300-1000mm, 1000-3000mm 

30-300mm, 300-3000mm

30-150mm, 150-1500mm 

150-1000mm, 1000-1500mm 

Accuracy (measurement of 1m calibration beam)

Better than 

2μm RMS 10-30mm

2μm RMS 30-100mm

Data storage requirements

< 2MB per kilometre of rail

Filter, user-selectable

band-pass, high-pass or low-pass

wavelength of 5-5000mm

Weight 

20kg in carrying case

8kg for instrument with laptop on rail

Options

measurement of track with different gauge

software to concatenate data files

software to detect and assess severity of welds

training course

 

TAG: