Your location£ºhome > News >

Full automatic stopping device

2017-02-22 09:49      Click£ºtimes
Auto stop device product details
ZZC660 type automatic car arrester is our company according to "coal mine safety regulations" on the "slopelane rail car field slope changing points within the installation, in order to prevent the occurrence of car accidents on specified field" development. When the vehicle needs to pass, the device automatically opens the device according to the operation order, and then the vehicle is closed immediately after being passed, and the buffering function is ensured.
Product composition and characteristics of automatic stop
ZZC660 type automatic car arrester by high sensitivity, good anti-interference performance of the sensor, intelligent controller, the control function is strong, reliable electric push rod and the car arrester control switch, etc. the inclined wells on anti running device.
(1) the sensor with novel design, high sensitivity and strong anti-interference ability is used to ensure the detection sensitivity of the device and ensure the reliability of the device;
(2) the photoelectric isolation technology is adopted, and the anti-jamming performance is good;
(3) the closing time of the retarder can be preset;
(4) ZZC660 type automatic stop device is easy to install and easy to use.
Application scope of automatic stopping device
ZZC660 type automatic car arrester for coal, metal ore and nonmetallic ore yard, automatic monitoring, and control traffic and to prevent passage of the car running.
Working condition of automatic stopping device
ZZC660 automatic stop device should be able to work under the following environmental conditions:
(1) temperature: 0 DEG C ~ 40 c;
(2) average relative humidity: <95%RH (+25 C)
(3) atmospheric pressure: (80 ~ 110) kPa
(4) the dangerous places suitable for coal mine methane and coal dust explosive gas, corrosive gas but without damage to the insulation.
The worst of the storage conditions of ZZC660 type automatic car arrester can withstand:
(1) high temperature: +60 c;
(2) low temperature: -40 c;
(3) vibration: 50m/s2;
(4) impact: 500m/s2.
Technical parameters of automatic stopping device
(1) operating voltage: AC660V + + 10%, 50Hz;
(2) I0:130mA C0:10 intrinsically safe parameters: U0:14.5VDC F L0:3mH;
(3) explosion proof type: Mine Flameproof and intrinsically safe type, explosion proof mark: Exd[ib]I.
TAG£º