ATM9 Main Transformer
EMU Type ATM9 Main Transformer
Type£ºATM9
Usage: Type CRH2 EMU with speed of 200KM/h and above
Main technical features
Mode: Single-phase£¬ shell-type£¬ non-pressure sealed type;
Mode of rectification: Input current sine wave frequency modulation multiple mode;
Insulation class: Special A class insulation;
Cooling method: Oil circulation air cooling method;
Total weight: 2910KG£¨Including electric supply fan£©£»
Main technical parameters
¡¡Winding |
¡¡Primary winding |
¡¡Secondary winding |
¡¡Tertiary winding |
Capacity£¨KVA£© |
¡¡3060 |
¡¡2570 |
¡¡490 |
¡¡Voltage£¨V£© |
¡¡25000 |
¡¡2570 |
¡¡400 |
¡¡Current£¨A£© |
¡¡122 |
¡¡857×2 |
¡¡1225 |
¡¡Frequency£¨Hz£© |
¡¡50 |
||
¡¡Rated class |
¡¡Continuous rating |